The drying group.
LVACUUM PUMP SYSTEM PROCESS.
The vacuum pump system process has been designed to dry power transformers. Indeed, vacuum pumps enable transformer vacuum degasification and dehydration.
|
PV2E 500 |
PV2E 1000 |
PV3E 1000 |
PV2E 2000 |
| Flow in m3/h (primary) |
170 |
240 |
240 |
640 |
| Ultimate vacuum in mbar |
0.08 |
0.08 |
0.08 |
0.08 |
| Motor power in kw |
4 |
5,5 |
5,5 |
15 |
| Speed of rotation in rpm |
1,500 |
1,500 |
1,500 |
1,500 |
| Oil capacity in litres |
5 |
8.5 |
8.5 |
35 |
| Flow in m3/h (first roots ) |
500 |
1,000 |
500 |
2,000 |
| Motor power in kw |
2.2 |
4 |
2.2 |
7.5 |
| Speed of rotation in rpm |
3,000 |
3,000 |
3,000 |
3,000 |
| Oil capacity in litres |
1.2 |
1.8 |
1.2 |
1.8 |
| Flow in m3/h (second roots ) |
- |
- |
1,000 |
- |
| Motor power in kw |
- |
- |
4 |
- |
| Speed of rotation in rpm |
- |
- |
3,000 |
- |
| Oil capacity in litres |
- |
- |
3.5 |
- |
| Measure of vacuum |
manometer |
manometer |
manometer |
manometer |
| Diam. of vacuum connection |
50 |
65 |
65 |
80 |

Vacuum motor pump.
ARRAS MAXEI vacuum pump systems are equipped with a 2 or 3-staged motor-pump , made of 1 oil sealed rotary vane type pump with filter, check valve and air ballast and a 1 or 2 roots .The connection to the transformer is done through a manifold with appropriate diameter fitted with an exhaust electrovalve, a safety valve, and an insulating valve.
|