The drying group.

text text

LVACUUM PUMP SYSTEM PROCESS.
The vacuum pump system process has been designed to dry power transformers. Indeed, vacuum pumps enable transformer vacuum degasification and dehydration.

PV2E 500 PV2E 1000 PV3E 1000 PV2E 2000
Flow in m3/h (primary) 170 240 240 640
Ultimate vacuum in mbar 0.08 0.08 0.08 0.08
Motor power in kw 4 5,5 5,5 15
Speed of rotation in rpm 1,500 1,500 1,500 1,500
Oil capacity in litres 5 8.5 8.5 35
Flow in m3/h (first roots ) 500 1,000 500 2,000
Motor power in kw 2.2 4 2.2 7.5
Speed of rotation in rpm 3,000 3,000 3,000 3,000
Oil capacity in litres 1.2 1.8 1.2 1.8
Flow in m3/h (second roots ) - - 1,000 -
Motor power in kw - - 4 -
Speed of rotation in rpm - - 3,000 -
Oil capacity in litres - - 3.5 -
Measure of vacuum manometer manometer manometer manometer
Diam. of vacuum connection 50 65 65 80

text

Vacuum motor pump.
ARRAS MAXEI vacuum pump systems are equipped with a 2 or 3-staged motor-pump , made of 1 oil sealed rotary vane type pump with filter, check valve and air ballast and a 1 or 2 roots .The connection to the transformer is done through a manifold with appropriate diameter fitted with an exhaust electrovalve, a safety valve, and an insulating valve.